20-Tanker (2006): Difference between revisions

From Rockland Apparatus
Jump to navigation Jump to search
Other Admin (talk | contribs)
mNo edit summary
Other Admin (talk | contribs)
m Text replacement - "| year = 2006 | manufacturer" to "| year = {{Start date and age|2006|df=y}} | manufacturer"
 
Line 3: Line 3:
| image          = File:20-Tanker_2006.jpg
| image          = File:20-Tanker_2006.jpg
| caption        =  
| caption        =  
| year            = 2006
| year            = {{Start date and age|2006|df=y}}
| manufacturer    = Pierce
| manufacturer    = Pierce
| apparatus_type  = Pumper
| apparatus_type  = Pumper

Latest revision as of 23:09, 24 March 2019

20-Tanker
Overview
Year 2006; 18 years ago (2006)
Manufacturer Pierce
Type Pumper
Subsequently Greenville Engine 703
Chronology
Predecessor 1991 Pierce Pumper (20-Tanker)
Successor 2014 Seagrave Rescue-Pumper (20-Tanker)


General

  • Apparatus Type: Pumper
  • Apparatus Sub Type: Rescue-Pumper
  • Manufacturer: Pierce
  • Year: 2006
  • Serial Number: 17154
  • VIN: 4P1CL01H36A005759
  • Color: White over red
  • NIMS Resource Typing: Engine Type I

Chassis/Cab

  • Model: Lance 2000
  • Cab Material: Aluminum
  • Doors: 4
  • Raised Roof: 22"
  • Front Bumper: Extended with preconnect
  • Length: 94 inches (7 ft 10 in) crew cab
  • Tilt: Split

Drivetrain

  • Propulsion: Diesel
  • Engine Make/Model: Detroit Diesel Series 60
  • Engine Specs: 14.0 L, 470 hp, 1650 lb-ft, Inline 6
  • Transmission Make/Model: Allison 4000 EVS
  • Transmission Specs: 5-speed automatic

Pump & Tank

  • Pump Make/Model: Waterous CMU
  • Pump Capacity: 2000 GPM, two-stage
  • Pump Location: Midship
  • Panel Location: Enclosed top
  • Drive Type: Split-shaft
  • Water Capacity: 1200 USG
  • Foam System: Husky 10
  • Foam Type: Class A and Class B
  • Foam Capacity: 25 USG (Class A), 25 USG (Class B)
  • Hose Reels: 1 booster and 1 forestry above pump

Body

  • Material: Aluminum

Equipment

  • Generator: Harrison MPC 15 kW
  • Reels: 1 electric, 1 hydraulic
  • Winch: Warn XD9000i portable, 9000 lb

Dimensions

Construction

  • Factory: Appleton, WI
  • Dealer: Tyler Fire Equipment
  • Delivery Date: January 17, 2006

Disposition

  • Out of Service Date: September 13, 2014
  • Purchaser: Greenville Fire District, Greenville (Orange County), NY
  • Misc. History: Fraternal twin to 20-2001 (Job #17155).